-
中文名稱:人胃泌酸調節素酶聯免疫試劑盒
-
貨號:CSB-E12948h
-
規格:96T/48T
-
價格:¥3600/¥2500
-
其他:
產品詳情
-
產品描述:人胃泌酸調節素酶聯免疫試劑盒(CSB-E12948h)為雙抗夾心法ELISA試劑盒,定量檢測血清、血漿、組織培養上清液、尿液、組織勻漿樣本中的OXM含量。試劑盒檢測范圍為0.312 ng/mL-20 ng/mL,適用于體外研究場景下OXM的表達水平分析,可為能量代謝調控機制研究、胃腸道功能探索及代謝性疾病分子機制研究提供可靠數據支持,滿足基礎科研與藥物研發中對OXM定量檢測的需求。本品僅用于科研,不用于臨床診斷,產品具體參數及操作步驟詳見產品說明書。
-
縮寫:OXM
-
種屬:Homo sapiens (Human)
-
樣本類型:serum, plasma, cell culture supernates, urine, tissue homogenates
-
檢測范圍:0.312 ng/mL-20 ng/mL
-
靈敏度:0.078 ng/mL
-
反應時間:1-5h
-
樣本體積:50-100ul
-
檢測波長:450 nm
-
研究領域:Metabolism
-
測定原理:quantitative
-
測定方法:Sandwich
-
精密度:
Intra-assay Precision (Precision within an assay): CV%<8% Three samples of known concentration were tested twenty times on one plate to assess. Inter-assay Precision (Precision between assays): CV%<10% Three samples of known concentration were tested in twenty assays to assess. -
線性度:
To assess the linearity of the assay, samples were spiked with high concentrations of human Oxyntomodulin in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay. Sample Serum(n=4) 1:1 Average % 89 Range % 83-94 1:2 Average % 84 Range % 80-89 1:4 Average % 95 Range % 89-99 1:8 Average % 92 Range % 88-96 -
回收率:
The recovery of human Oxyntomodulin spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section. Sample Type Average % Recovery Range Serum (n=5) 95 91-99 EDTA plasma (n=4) 98 92-103 -
標準曲線:
These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed. ng/ml OD1 OD2 Average Corrected 20 2.263 2.181 2.222 2.042 10 1.761 1.791 1.776 1.596 5 1.263 1.201 1.232 1.052 2.5 0.766 0.723 0.745 0.565 1.25 0.443 0.417 0.430 0.250 0.625 0.274 0.253 0.264 0.084 0.312 0.267 0.282 0.275 0.095 0 0.181 0.179 0.180 -
數據處理:
-
貨期:3-5 working days
引用文獻
- NDRG1 Activity in Fat Depots Is Associated With Type 2 Diabetes and Impaired Incretin Profile in Patients With Morbid Obesity Iurii Stafeev,Frontiers in endocrinology,2022
- РЕМИССИЯ САХАРНОГО ДИАБЕТА 2 ТИПА ПРИ ИСПОЛЬЗОВАНИИ МЕДИКАМЕНТОЗНОГО (ЛИРАГЛУТИД) И БАРИАТРИЧЕСКИХ МЕТОДОВ ЛЕЧЕНИЯ: СРОКИ НАСТУПЛЕНИЯ, ПРОГНОСТИЧЕСКИЕ ФАКТОРЫ, МЕХАНИЗМЫ ИА СКЛЯНИК,/,2020
- Low AS160 and high SGK basal phosphorylation associates with impaired incretin profile and type 2 diabetes in adipose tissue of obese patients Iurii S. Stafeev, et al,Diabetes Research and Clinical Practice,2019
- Specificity and sensitivity of commercially available assays for glucagon and oxyntomodulin measurement in human Bak MJ et al,Eur J Endocrinol,2014
- Effects of a brown beans evening meal on metabolic risk markers and appetite regulating hormones at a subsequent standardized breakfast: a randomized cross-over study Nilsson A et al,PLoS One,2013
相關產品
Most popular with customers
-
Human Transforming Growth factor β1,TGF-β1 ELISA kit
Detect Range: 23.5 pg/ml-1500 pg/ml
Sensitivity: 5.8 pg/ml
-
-
-
Mouse Tumor necrosis factor α,TNF-α ELISA Kit
Detect Range: 7.8 pg/ml-500 pg/ml
Sensitivity: 1.95 pg/ml
-
-
-
-